Stop paying for power the process never uses.
Most industrial plants run motors flat out and throw the surplus away in valves, dampers and slipping belts. Our power utilisation intervention fits variable speed drives where the load varies, and targets a reduction in power cost of up to forty percent.
Correction units against variable speed drives
Both appear on the same shortlist when a factory decides its power bill is too high. They do very different things, and only one of them changes what the plant actually consumes.
Treats the demand, not the consumption
A capacitor bank supplies the reactive current the motors need, so the supply carries less current and the demand and penalty portion of the bill falls. Useful, and often worth doing. But the motor still turns at full speed whether the process needs it or not, so the units of energy you burn stay exactly where they were.
Matches the motor to the work in front of it
The drive varies motor speed to what the process actually calls for. On pumps and fans the power drawn falls far faster than the speed does, so trimming a fan or pump back to what the duty needs takes a large bite out of consumption rather than out of the tariff line. The drive also presents a high displacement power factor at its input, so a good part of what the capacitor bank was fitted to fix goes away with it.
Starting stops being an event
Direct on line starting slams full torque into belts, couplings, gearboxes and shafts, and pulls a starting current several times running current. A drive ramps the machine up under control, which lengthens the life of the driven equipment and takes the peak off your maximum demand.
Process control you did not have before
Speed becomes a setting rather than a fixed fact of the machine. Feed rates, air volumes and flow can be tuned to the product instead of throttled down after the fact.
How the saving is found and proved
We do not quote a percentage before we have measured your plant. The figure comes out of the load profile, and it is checked against the meter afterwards.
Current, voltage, power factor and running hours logged on the main drives, so the bill is broken down into machines rather than guessed at.
Oversized motors, pumps throttled at a valve, fans running against a damper, conveyors running empty between batches, compressors blowing off. Each one is energy bought and discarded.
Drives sized and installed on the loads that vary, with control tied to the process signal, so the machine follows demand instead of running at one speed all shift.
The same measurements taken again after commissioning, so the saving is a number from your own supply, not a claim from a brochure.
The drive is intelligent enough to tell you what the plant is doing
A drive is a meter, a protection device and a condition monitor that happens to also run the motor. Most plants never read any of it. We set it up so you can.
Conveyors, milling and crushing
These are the plants where a drive earns its keep twice: once on the power bill, and again on the clogging and stalling that costs a shift.
Conveyors
A loaded belt that has stopped will not restart across the line without slipping, snatching or tripping. The drive ramps it away under full load, limits torque so nothing tears, and can inch or reverse the belt to clear a build up.
Milling
Feed rate is matched to what the mill can take, so it is neither starved nor choked. Rising current tells you a choke is coming before the mill is packed and someone has to dig it out by hand.
Crushing
Controlled starting against a loaded chamber, torque limiting to protect the drive train on tramp material, and speed set to the product rather than to whatever the motor happens to run at.
Find out what your plant is actually spending.
We measure first. The saving is quoted from your own figures.